<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Chromatographer &#187; separation</title>
	<atom:link href="http://www.chromatographer.com/tag/separation/feed" rel="self" type="application/rss+xml" />
	<link>http://www.chromatographer.com</link>
	<description>resolution matters</description>
	<lastBuildDate>Thu, 02 Sep 2010 06:08:27 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.6</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Separation of small molecules on organic polymer monoliths</title>
		<link>http://www.chromatographer.com/separation-of-small-molecules-on-organic-polymer-monoliths</link>
		<comments>http://www.chromatographer.com/separation-of-small-molecules-on-organic-polymer-monoliths#comments</comments>
		<pubDate>Mon, 08 Feb 2010 17:54:49 +0000</pubDate>
		<dc:creator>Jiri Urban</dc:creator>
				<category><![CDATA[Monoliths]]></category>
		<category><![CDATA[organic polymer]]></category>
		<category><![CDATA[separation]]></category>
		<category><![CDATA[small molecules]]></category>
		<category><![CDATA[stationary phase]]></category>

		<guid isPermaLink="false">http://www.chromatographer.com/?p=500</guid>
		<description><![CDATA[Because of lack of small pores it is difficult to separate small molecules with polymer monoliths in isocratic mode. We have prepared monolithic capillary columns and then hypercrosslinked them to afford a monolith containing an array of small pores [1].
This monolithic column affords good separation of uracil and alkylbenzenes in isocratic mobile phase mode (a [...]]]></description>
			<content:encoded><![CDATA[<p></p><p>Because of lack of small pores it is difficult to separate small molecules with polymer monoliths in isocratic mode. <a title="Hypercrosslinked polymer monoliths for separation of small molecules" href="http://pubs.acs.org/doi/abs/10.1021/ac100008n">We have prepared</a> monolithic capillary columns and then hypercrosslinked them to afford a monolith containing an array of small pores [1].</p>
<p><span id="more-500"></span>This monolithic column affords good separation of uracil and alkylbenzenes in isocratic mobile phase mode (a column efficiency as high as 73 000 plates/m was determined for uracil) and also proved useful for separations in size exclusion mode.</p>
<h2>Organic polymer monoliths and small molecules</h2>
<p>Compare to silica based monoliths, <strong>porous polymer monoliths</strong> contain very small or even no concentration of small pores in their porous structure. Therefore, they exhibit much <strong>smaller surface areas</strong> (tens of square meter per gram) and usually are not suitable for separation of small molecules. Several approaches were explored to improve this drawback of organic polymer monoliths: copolymerization of dimethacrylates differing in the length and branching of the fragment connecting the polymerizable units[2]; the termination of the polymerization reaction at an early stage<strong> </strong>[3,4] to achieve large surface areas; and the use of high polymerization temperatures [5,6].</p>
<p>However, it has always proven difficult to prepare polymer monoliths possessing both large through pores and a multiplicity of small pores in a single step and <strong>alternative approaches needed to be developed</strong>.</p>
<h2>Hypercrosslinking modification</h2>
<div id="attachment_511" class="wp-caption alignright" style="width: 260px">
	<img class="size-full wp-image-511" title="Separation of small molecules with organic polymer monolith" src="http://www.chromatographer.com/wp-content/uploads/2010/02/separation.jpg" alt="Separation of small molecules with organic polymer monolith" width="260" height="388" />
	<p class="wp-caption-text">Separation of uracil (1) and small alkylbenzenes (2-7) with organic polymer monolith. See Ref. 1 for more details.</p>
</div>
<p><strong>Hypercrosslinking</strong>, pioneered by Davankov several decades ago [7-10] enables the preparation of large surface area materials from preformed polymer precursors. The original implementation used linear polystyrene, which was <strong>cross-linked via Friedel-Crafts alkylation</strong> to afford <strong>materials containing mostly small pores</strong> [11].</p>
<p>The typical porous monolithic structure consisting of interconnected microglobules results from phase separation during polymerization of a mixture of monomers and porogens. For poly(styrene-<em>co</em>-vinylbenzyl chloride-<em>co</em>-divinylbenzene) monoliths less than ideal reactivity ratios for monomers such as styrene, chloromethylstyrene, and divinylbenzene lead to <strong>polymer microglobules amenable to hypercrosslinking</strong>. The divinyl monomer polymerizes faster, and the remaining monomer mixture becomes significantly richer in the monovinyl monomers as the polymerization reaction nears completion. This mixture then affords only slightly cross-linked chains attached to the surface of highly crosslinked microglobular scaffolds. When the pores are filled with a thermodynamically good solvent such as 1,2-dichloroethane, this surface polymer layer is solvated.</p>
<h2>Capillary liquid chromatography</h2>
<p>The precursor column performs poorly as all alkylbenzenes are less retained and eluted in a single broad peak. In contrast, <strong>baseline separation of all alkylbenzenes</strong> is obtained with the column after hypercrosslinking (see Figure). On the other hand, gradient separation of the proteins is better on the non-modified column because of negative effect of the small pores on the gradient separation [12]. Finally, because of significant concentration of small pores, these columns can be used for <strong>separation of polymers in size-exclusion chromatography</strong>.</p>
<p><a title="Hypercrosslinked polymer monoliths for separation of small molecules" href="http://pubs.acs.org/doi/abs/10.1021/ac100008n">Our work</a> clearly demonstrates the possibility of postpolymerization hypercrosslinking of the monolithic stationary phase to afford columns for efficient isocratic separation of small molecules in reversed phase and polymers in size exclusion modes.</p>
<h2>References</h2>
<ol>
<li>Urban, J., Svec, F., Fréchet, J.M.J. <a href="http://pubs.acs.org/doi/abs/10.1021/ac100008n"><em>Anal. Chem. </em>2010, 82.</a></li>
<li>Xu, Z., Yang, L. and Wang, Q. <em>J. Chromatogr. A</em> 2009, 1216, 3098 – 3106.</li>
<li>Wang, Q., Svec, F. and Fréchet, J. M. J. <em>Anal. Chem.</em> 1995, 67, 670 – 674.</li>
<li>Trojer, L., Bisjak, C. P., Wieder, W. and Bonn, G. K. <em>J. Chromatogr. A</em> 2009, 1216, 6303 – 6307.</li>
<li>Peters, E. C., Svec, F. and Fréchet, J. M. J. <em>Adv. Mater.</em> 1999, 11, 1169 – 1181</li>
<li>Meyer, U., Svec, F., Fréchet, J. M. J., Hawker, C. J. and Irgum, K. <em>Macromolecules</em> 2000, 33, 7769 – 7775.</li>
<li>Davankov, V. A., Rogozhin, S. V. and Tsyurupa, M. P. Macronet Polystyrene Structures for Ionites and Method of Producing Same. <em>U.S. Patent</em> 3,729,457, April 24, 1973.</li>
<li>Pastukhov, A. V., Tsyurupa, M. P. and Davankov, V. A. <em>J. Polym. Sci., Polym. Phys. </em>1999, 37, 2324 – 33.</li>
<li>Davankov, V. A. and Tsyurupa, M. P. <em>React. Polym.</em> 1990, 13, 27 – 42.</li>
<li>Davankov, V. A., Tsyurupa, M., Ilyin, M. and Pavlova, L. <em>J. Chromatogr. A</em> 2002, 965, 65 – 73.</li>
<li>Tsyurupa, M. P. and Davankov, V. A. <em>React. Funct. Polym.</em> 2006, 66, 768 – 779.</li>
<li>Urban, J., Moravcova, D. and Jandera, P. <em><span>J. Sep. Sci.</span> </em><span>2006</span>,  <span>29</span>,  <span>1064</span>– <span>73</span></li>
</ol>
]]></content:encoded>
			<wfw:commentRss>http://www.chromatographer.com/separation-of-small-molecules-on-organic-polymer-monoliths/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>What is chromatography?</title>
		<link>http://www.chromatographer.com/what-is-chromatography</link>
		<comments>http://www.chromatographer.com/what-is-chromatography#comments</comments>
		<pubDate>Fri, 07 Aug 2009 04:07:36 +0000</pubDate>
		<dc:creator>Jiri Urban</dc:creator>
				<category><![CDATA[Chromatography]]></category>
		<category><![CDATA[column]]></category>
		<category><![CDATA[GC]]></category>
		<category><![CDATA[HPLC]]></category>
		<category><![CDATA[separation]]></category>
		<category><![CDATA[Theory]]></category>

		<guid isPermaLink="false">http://www.chromatographer.com/?p=1</guid>
		<description><![CDATA[Chromatography is analytical chemistry method which is used (and useful) for the separation of complex mixtures of chemical compounds. The main mechanism of the separation is repeatable distribution of the tested compound in between two different phases.

Usually, one phase is solid, fixed in the separation device and the other is moving and flows through the [...]]]></description>
			<content:encoded><![CDATA[<p></p><p>Chromatography is analytical chemistry method which is used (and useful) for the separation of complex mixtures of chemical compounds. The main mechanism of the separation is repeatable distribution of the tested compound in between two different phases.</p>
<p><span id="more-1"></span></p>
<p>Usually, one phase is solid, fixed in the separation device and the other is moving and flows through the unit. If gas is a second phase, we are referring to the <strong>gas chromatography</strong>, in case of liquid as a second phase the name is <strong>liquid chromatography</strong>.</p>
<p><a href="http://www.chromatographer.com/wp-content/uploads/2009/08/Column_chromatography_sequence1.png"><img src="http://www.chromatographer.com/wp-content/uploads/2009/08/Column_chromatography_sequence1.png" alt="Scheme of chromatography" title="Scheme of chromatography" width="350" height="106" class="alignleft size-full wp-image-21" /></a> The device where separation takes place is called <strong>chromatographic column</strong>. This cylindrical shape column is filled with the different kinds of materials – stationary phases. These materials are usually spherical silica particles with different, but well defined, surface chemistry.</p>
<p>The mobile phase flows through the column together with sample (mixture of compounds). Each compound has various affinity to the surface of stationary phase and therefore is separated form each other. In case of ideal state all compounds are eluted from the column in separated bands.</p>
<p>Various techniques are used to recognize these bands and transform them into the signal. In most of the cases the signal draws <strong>chromatographic peak</strong> – the “hill like” curve describing <a title="read more on Wikipedia" href="http://en.wikipedia.org/wiki/Gauss_distribution">Gauss distribution</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.chromatographer.com/what-is-chromatography/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
